CoaguCheck XS Plus
CoaguChek® XS Plus system – PT/INR monitoring tailored to healthcare professionals’ needs
The latest generation in coagulation monitoring, the CoaguChek® XS Plus system is specifically designed to meet the requirements of healthcare professionals, thanks to its specific data management, quality control and connectivity features.

The CoaguChek® XS Plus system produces results equivalent to those obtained with reference laboratory methods. It also compares very closely to the patient’s device, the CoaguChek® XS system, as it uses the same technology and the same strip.
With the CoaguChek® XS Plus professional system, you measure the PT/INR value within one minute, using a drop of blood from the fingertip, and can immediately adjust your patient’s therapy within the comfort and safety of your practice.
With its innovative and practical features, the CoaguChek® XS Plus system helps you to provide on-the-spot high quality PT/INR results, affording you and your patients more quality time and increased peace of mind when monitoring Vitamin K antagonist therapy.
More safety
Safety features
- On-board single-channel strip control (OS2C) to automatically check the strip’s integrity
- On-board-integrated-system (OBIS) controls, continuous monitor/strip integrity checks
- Optional quality control (QC) lockout: the instrument only works if QC is passed

Low ISI PT reagent
- A human recombinant tissue factor based reagent (ISI=approx. 1.0)
- Exceeding WHO recommendations (ISI < 1.7)
Integrated data management functions
- Download, synchronize and upload all relevant data
- Stores 1000 patients and 500 QC test results
- Data storage for up to 60 code chips
Quality comparable to laboratory results
- Results correlate well with laboratory results1
- Optional one-level liquid quality control to comply with local regulations
Greater comfort
Convenient for you
- Handheld and portable
- Battery operated or external power supply
- Full graphical display with touch screen
- Simple setup and intuitive menu
- Optional rechargeable battery pack allowing for more economical operation and flexibility when visiting patients

Comfortable for your patients
- Immediate results
- Immediate start or adjustment of therapy
- Virtually pain free: only one drop of capillary whole blood (8µl) from the fingertip to get a precise1 INR result — no need for venous blood sampling
- Top- and two-side dosing option
Optimized workflow
Improving your workflow
- Reduced logistics: e.g., no need to send venous blood samples or patients to the laboratory
- More quality time for you and your patients

IT connectivity
- Connectivity to cobas IT 1000 solution (Roche’s Point-of-Care data management solution) or to your network via various ports
- Compliance with your local data management requirements
Simple and fast handling
- Only a few easy steps to get fast INR results (1 min)
More quality time for patients
- A better relationship can result in more loyal patients
- Fewer steps before decision on therapy adjustment
Improved clinical outcome
More frequent testing
- Leads to an increased percentage of INR values within the therapeutic range2
- Leads to a minimization of adverse effects2
- Enabled by PoC testing
- Enables therapy adjustments within a few minutes
- Enables more effective treatment

As both CoaguChek® XS Plus and CoaguChek® XS systems provide equivalent results, your patient can easily switch to Patient Self-Testing/Patient Self-Management at home, provided you believe the patient can be trained. Self-management helps patients to improve their quality of life and gain greater independence, yet feel safe under your guidance.
For more information on the CoaguChek® XS Plus system, please visit coaguchek.com
______________________________________________________________________
1 W. Plesch et al.: Study LB 157-2005; Evaluation of the CoaguChek® XS Plus System - Equivalency to the CoaguChek® XS System; (http://www.coaguchek.com/com/?target=/com/professionals/news; released on: 1 April 2006) Note: precise with r=0.989 in method comparison to Innovin
2 D. Horstkotte et al.: Optimal frequency of patient monitoring and intensity of oral anticoagulation therapy on valvular heart disease; (Journal of Thrombosis and Thrombolysis; 1998; 5:19-24)